1.00 $
Reference Number
RF184683
Title
Endress + Hauser iTEMP TMT162 temperature transmit
Phone
Description
Endress + Hauser iTEMP TMT162 temperature transmitter
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)
Endress + Hauser FDU90-RG4AA Ultrasonic measurement Time-of-Flight Prosonic FDU90
Field of application
The FDU90 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 3m (9.8ft), solids 1.2m (3.9ft).
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
Sensor for continuous, non-contact level measurement of fluids and bulk materials in silos, on belts, stockpiles and in crushers. Also flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +4bar (+10 to +58psi)
Maximum measuring range: Liquids 3m (9.8ft), solids 1.2m (3.9ft)
Blocking distance: 0.07m (0.23ft)
International explosion protection certificates
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
Benefits
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
Hermetically welded PVDF sensor for highest chemical resistance
Suited for rough ambient conditions thanks to separate installation from the transmitter
(up to 300m)
Reduced build-up formation because of the self-cleaning effect
Integrated automatic sensor detection for transmitters FMU90 /FMU95 for simple commissioning
Weather resistant and flood-proof (IP 68)
Integrated heating against a build-up of ice at the sensor (optional) ensures reliable measurement
Ultrasonic measurement Time-of-Flight Prosonic FDU90
Ultrasonic measurement Time-of-Flight Prosonic FDU91
Ultrasonic measurement Time-of-Flight Prosonic FDU91F
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes. The remote configurable transmitter transfers and monitors converted signals from RTD sensors and thermocouples as well as from resistance and voltage signals using selectively HART®, FOUNDATION Fieldbus™-, PROFIBUS® PA-communication. It visualizes the signals on its own backlit display. A field housing allows a direct connection in harsh process areas as well as in hygienic applications as option.
Universal input usable for resistance thermometer (RTD), thermocouple (TC), resistance thermometer (Ω), voltage transmitters (mV)
Endress + Hauser FDU90-RG4AA Ultrasonic measurement Time-of-Flight Prosonic FDU90
Field of application
The FDU90 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 3m (9.8ft), solids 1.2m (3.9ft).
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
Sensor for continuous, non-contact level measurement of fluids and bulk materials in silos, on belts, stockpiles and in crushers. Also flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.
Process connection: Thread
Temperature: -40 to +80°C (-40 to +176°F)
Pressure: +0.7 to +4bar (+10 to +58psi)
Maximum measuring range: Liquids 3m (9.8ft), solids 1.2m (3.9ft)
Blocking distance: 0.07m (0.23ft)
International explosion protection certificates
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
Benefits
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
Hermetically welded PVDF sensor for highest chemical resistance
Suited for rough ambient conditions thanks to separate installation from the transmitter
(up to 300m)
Reduced build-up formation because of the self-cleaning effect
Integrated automatic sensor detection for transmitters FMU90 /FMU95 for simple commissioning
Weather resistant and flood-proof (IP 68)
Integrated heating against a build-up of ice at the sensor (optional) ensures reliable measurement
Ultrasonic measurement Time-of-Flight Prosonic FDU90
Ultrasonic measurement Time-of-Flight Prosonic FDU91
Ultrasonic measurement Time-of-Flight Prosonic FDU91F
Condition
New
City/Region
Akhaltsikhe
- 23 Views