Endress+Hauser CLD132-PMV110AB1 Conductivity compa

1.00 $
Reference Number
RF819936
Title
Endress+Hauser CLD132-PMV110AB1 Conductivity compa
Description
Endress+Hauser CLD132-PMV110AB1 Conductivity compact device Smartec CLD132

Field of application
Smartec CLD132 is a measuring system for inductive conductivity. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a stainless steel temperature sensor that gives you an ultrafast temperature response for reliable measurement in separation applications.

Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com

Smartec CLD132 is suited to applications such as:Alkaline/acid concentration control in remaking
Phase separation of product/water and product/product mixtures in pipe systems
Product monitoring
Smartec CLD132 features the following protocols and interfaces:
0/4...20mA
HART
PROFIBUS DP
PROFIBUS PA

Benefits
Engineered for quick temperature response
Low risk of soiling due to encapsulated sensor
Insensitive to polarization
Measuring principle
Inductive

Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com


Application
- Alkali/acid concentration control - phase separation in pipe systems - monitoring and control of bottle cleaning systems - product monitoring in breweries, dairies and the beverage industry - CIP system control

Characteristic
Compact measuring system for an inductive conductivity measurement special made for media with a high conductivity.

Measuring range
100 µS/cm - 2000 mS/cm

Measuring principle
Inductive measuring system including transmitter and sensor.

Design
Compact transmitter made of stainless steel with an inductive sensor made of PEEK in a separate or compact version.

Material
Housing: Stainless steel 1.4301 polished Window: Polycarbonate Sensor: PEEK, stainless steel 1.4435 Sealing: Chemraz

Process temperature
max. 140°C (max. 30 min.)
284°F (max. 30 min.)

Process pressure
max. 12 bar (90°C)
(174 psi(194°F))

Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com

Temperature sensor:Pt100
Ex certification:No
Ingress protection:IP67
Input:One-channel transmitter incl. temperature.
Output / communication
Conductivity and temperature 0/4-20 mA, HART, Profibus.

CLD132-XCS1328AA2

CLD132-PMV130AB1
Condition
New
City/Region
Akhaltsikhe
  • 27 Views
There are no bids currently
Select a label or click "Other" to send comments
Loading...
Are you sure you want to cancel your report?
The account with the email address already exists on the site. To synchronize with Social Network Login plugin please enter the password to your account on the site.
Sign in
Username
Password
Forgot your password? Remind