1.00 $
Reference Number
RF190534
Title
ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Phone
Description
ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
SF810INT-LOS-UV-T-C-W | ABB | Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
General Information of ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Manufacturer : ABB
Product ID: SF810I-LOS-IR-T-W
Catalog Description:SF810INT-LOS-IR-T-C-W
Product Type : Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner
ABB Product Family:Combustion Instruments
Installation type : LOS = Scannerhead for Line Of Sight
Spectral range : UV
Cabling method, protection index, hazardous areas : T = Removable screw terminals (IP66/ IP67 and ATEX G/D
Housing : C-W = Conformal coating, Aluminium case
Weight : 1.3 Kg
Technical specifications
Property Value
Optical sensor Technology
IR versions: Si photodiode Spectral response peak @ 920nm
IR versions: Si photodiode Spectral response peak @ 920nm
VL versions: Si photodiode Spectral response peak @ 560nm
UV versions: SiC photodiode Spectral response peak @ 280nm
UVIR version: Si + SiC photodiode1 Spectral response peak @280nm and 920nm
1 Si and SiC photodiodes signals can be processed individually or both combined as per burner opertion
Power supply voltage 24VDC (-25%, +20% = 18 ÷ 29VDC )
Power supply current 150mA typical,
Power consumption3.6W typical, 4W max
Inrush current6A peak, 2ms settling time
Flame Relay Safe Relay
Contacts: 1 NO, for each relay
240 VAC / 1.5A; cycles ≥ 100,000
240 VDC / 100 mA
30 VDC / 300mA
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com
Minimum load 10mA, 5VDC
FFRT Flame Failure Response Time: 0.2s to 4s
Analog output (4-20mA) 4÷20 mA (R load <= 500Ω);Galvanically isolated;Precision: +/-5% f.s
Digital Inputs, 24 VDC
Nr. 2 digital inputs (opto coupled), to allow selection of one out of four different sets of parameters; return signal common to both inputs.
Nominal voltage 24VDC (5 mA typical)
Max Voltage 36 VDC;Off: < 5 VDC; On: > 18 Vdc
Communication ports
Two, redundant, RS-485 serial channels configurable in Profibus or Modbus protocols.
Profibus: max speed 12 Mbit/s
Modbus: max speed 115.200 bit/s
operating temperature
482° C (900° F) for VL and IR fiber optic cables
350° C (662° F) for UV and dual sensor UVIR fiber optic cable
Housing mounting thread
1” NPT male
Cable entry thread
¾ “ NPT female (N/A for connectorized versions)
Electrical connections(terminal versions)
Removable terminals with screws
Allowable cable section:
AWG24-AWG12, 0.2-2.5mm2 for Relay contacts (J1 connector)
AWG 28-AWG16, 0,08-1.5mm2 for all other terminals
SF810INT-LOS-UV-T-C-W | ABB | Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com
General Information of ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Manufacturer : ABB
Product ID: SF810I-LOS-IR-T-W
Catalog Description:SF810INT-LOS-IR-T-C-W
Product Type : Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner
ABB Product Family:Combustion Instruments
Installation type : LOS = Scannerhead for Line Of Sight
Spectral range : UV
Cabling method, protection index, hazardous areas : T = Removable screw terminals (IP66/ IP67 and ATEX G/D
Housing : C-W = Conformal coating, Aluminium case
Weight : 1.3 Kg
Technical specifications
Property Value
Optical sensor Technology
IR versions: Si photodiode Spectral response peak @ 920nm
IR versions: Si photodiode Spectral response peak @ 920nm
VL versions: Si photodiode Spectral response peak @ 560nm
UV versions: SiC photodiode Spectral response peak @ 280nm
UVIR version: Si + SiC photodiode1 Spectral response peak @280nm and 920nm
1 Si and SiC photodiodes signals can be processed individually or both combined as per burner opertion
Power supply voltage 24VDC (-25%, +20% = 18 ÷ 29VDC )
Power supply current 150mA typical,
Power consumption3.6W typical, 4W max
Inrush current6A peak, 2ms settling time
Flame Relay Safe Relay
Contacts: 1 NO, for each relay
240 VAC / 1.5A; cycles ≥ 100,000
240 VDC / 100 mA
30 VDC / 300mA
Please contact me get more information
Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com
Minimum load 10mA, 5VDC
FFRT Flame Failure Response Time: 0.2s to 4s
Analog output (4-20mA) 4÷20 mA (R load <= 500Ω);Galvanically isolated;Precision: +/-5% f.s
Digital Inputs, 24 VDC
Nr. 2 digital inputs (opto coupled), to allow selection of one out of four different sets of parameters; return signal common to both inputs.
Nominal voltage 24VDC (5 mA typical)
Max Voltage 36 VDC;Off: < 5 VDC; On: > 18 Vdc
Communication ports
Two, redundant, RS-485 serial channels configurable in Profibus or Modbus protocols.
Profibus: max speed 12 Mbit/s
Modbus: max speed 115.200 bit/s
operating temperature
482° C (900° F) for VL and IR fiber optic cables
350° C (662° F) for UV and dual sensor UVIR fiber optic cable
Housing mounting thread
1” NPT male
Cable entry thread
¾ “ NPT female (N/A for connectorized versions)
Electrical connections(terminal versions)
Removable terminals with screws
Allowable cable section:
AWG24-AWG12, 0.2-2.5mm2 for Relay contacts (J1 connector)
AWG 28-AWG16, 0,08-1.5mm2 for all other terminals
Condition
New
City/Region
Batumi
District / Village
Avgia
- 22 Views