ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner

1.00 $
Reference Number
RF190534
Title
ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Description
ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner


SF810INT-LOS-UV-T-C-W | ABB | Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner

Please contact me get more information

Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website: www.cwlyautomation.com

General Information of ABB SF810INT-LOS-IR-T-C-W Safe Flame Scanner
Manufacturer : ABB

Product ID: SF810I-LOS-IR-T-W

Catalog Description:SF810INT-LOS-IR-T-C-W

Product Type : Uvisor™ SF810i Multi Fuel Integrated Safe Flame Scanner

ABB Product Family:Combustion Instruments

Installation type : LOS = Scannerhead for Line Of Sight

Spectral range : UV

Cabling method, protection index, hazardous areas : T = Removable screw terminals (IP66/ IP67 and ATEX G/D

Housing : C-W = Conformal coating, Aluminium case

Weight : 1.3 Kg

Technical specifications

Property Value

Optical sensor Technology

IR versions: Si photodiode Spectral response peak @ 920nm

IR versions: Si photodiode Spectral response peak @ 920nm

VL versions: Si photodiode Spectral response peak @ 560nm

UV versions: SiC photodiode Spectral response peak @ 280nm

UVIR version: Si + SiC photodiode1 Spectral response peak @280nm and 920nm

1 Si and SiC photodiodes signals can be processed individually or both combined as per burner opertion

Power supply voltage 24VDC (-25%, +20% = 18 ÷ 29VDC )

Power supply current 150mA typical,

Power consumption3.6W typical, 4W max

Inrush current6A peak, 2ms settling time

Flame Relay Safe Relay

Contacts: 1 NO, for each relay

240 VAC / 1.5A; cycles ≥ 100,000

240 VDC / 100 mA

30 VDC / 300mA


Please contact me get more information

Email:Mia@cwlyautomation.com
VK/Whatsapp/Telegram:+8613667120925
Website:https://www.cwlyautomation.com


Minimum load 10mA, 5VDC

FFRT Flame Failure Response Time: 0.2s to 4s

Analog output (4-20mA) 4÷20 mA (R load <= 500Ω);Galvanically isolated;Precision: +/-5% f.s

Digital Inputs, 24 VDC

Nr. 2 digital inputs (opto coupled), to allow selection of one out of four different sets of parameters; return signal common to both inputs.

Nominal voltage 24VDC (5 mA typical)

Max Voltage 36 VDC;Off: < 5 VDC; On: > 18 Vdc

Communication ports

Two, redundant, RS-485 serial channels configurable in Profibus or Modbus protocols.

Profibus: max speed 12 Mbit/s

Modbus: max speed 115.200 bit/s

operating temperature

482° C (900° F) for VL and IR fiber optic cables

350° C (662° F) for UV and dual sensor UVIR fiber optic cable

Housing mounting thread

1” NPT male

Cable entry thread

¾ “ NPT female (N/A for connectorized versions)

Electrical connections(terminal versions)

Removable terminals with screws

Allowable cable section:

AWG24-AWG12, 0.2-2.5mm2 for Relay contacts (J1 connector)

AWG 28-AWG16, 0,08-1.5mm2 for all other terminals
Condition
New
City/Region
Batumi
District / Village
Avgia
  • 22 Views
There are no bids currently
Select a label or click "Other" to send comments
Loading...
Are you sure you want to cancel your report?
The account with the email address already exists on the site. To synchronize with Social Network Login plugin please enter the password to your account on the site.
Sign in
Username
Password
Forgot your password? Remind